Memory Based Monitoring
Slimline
The small space solution for quicker downhole temperature response.
Canada Tech's Slimline memory tool offers exceptional quality and toughness in a small package. At only 3/4 inch diameter, it is ideal for 2 3/8 inch tubing, and is bolstered by large memory and low power consumption.
Why Slimline?
- Get quicker temperature response with reduced size
- Use in tubing as small as 2 3/8 inches
- Use in stimulation work – this thin tool won’t interrupt flow of the well
- Use for procedures that require a new battery for every application
Applications
- Limited space scenarios
- Tests of up to 3 months in duration
- Plunger lift
Slimline Specifications
| Pressure | |
|---|---|
| Maximum external pressure | 25 ksi |
| Sensor type | Piezo-resistive |
| Accuracy | <± 0.050% full scale |
| Accuracy Typical | ± 0.030% full scale |
| Long term stability | 0.1% full scale |
| Drift | < 3 psi per year |
| Resolution | 0.0003% full scale |
| Temperature | |
| Maximum temperature | 177°C |
| Accuracy | ± 0.6°C |
| Repeatability | ± 0.2°C |
| Resolution | 0.0001% full scale |
| Power | |
| Battery type | AA Lithium |
| Operating Voltage | 3.2 to 3.9 V |
| Memory | |
| Sampling interval | 1/100s, 1/10s, ≥1s |
| Capacity | 1,000,000 records |
| Record contents | Time, pressure, temperature, battery voltage |
See PDF link for the Slimline with 10 KSI Max Diff